IN1804 Seamless Scaling Switchers • SIS Configuration and Control 81
Command ASCII Command
(Host to Switcher)
Response
(Switcher to Host)
Additional Description
IP Control Port Commands (continued)
Passwords
NOTE: The initial passwords set at the factory are the serial number of the unit. However, if the unit is reset (via the ZQQQ
SIS command or the rear panel Reset button), this password reverts to no password.
Set administrator password
EX9!
CA
}
Ipa•
X9!]
Set the administrator password to
X9!
.
View administrator password
E
CA
}
****
]
or
]
In verbose modes 2 and 3:
Ipa•****
]
or Ipa
]
View the administrator password.
Reset (clear) administrator
password
E
•CA
}
Ipa•
]
Reset or clear the administrator
password.
Set user password
EX9!
CU
}
Ipu•
X9!]
Set the user password.
View user password
E
CU
}
****
]
or
]
In verbose modes 2 and 3:
Ipu•****
]
or Ipu
]
View the user password. If there is a
valid password, the response is ****
]
.
If there is no password, the response is
]
.
Reset (clear) user password
E
•CU
}
Ipu•
]
Reset or clear the user password.
KEY:
X9!
= Password
• Length is 1-128 characters.
• All human-readable characters are permitted except
|
.
• The password cannot be a single space.
• Passwords are case-sensitive.
• A user password cannot be assigned if no administrative password
exists. An E14 error code is returned.
• If the admin password is cleared, the user password is cleared also.
NOTE: If there is a valid password, the response is ****
]
. if there is no password, the response is
]
.