EasyManua.ls Logo

EZA ECB Series - User Manual

Default Icon
94 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
ECB Series User’s Manual
ECB25/35
PURE SINE WAVE INVERTER
EN
[Page 3]
ECB25/35
CONVERTISSEUR PUR SINUS
FR
[Page 47]

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the EZA ECB Series and is the answer not in the manual?

Summary

IMPORTANT SAFETY INFORMATION

General Safety Precautions

Essential safety guidelines for using the inverter, covering environmental exposure and general operation.

Battery Handling Precautions

Critical safety measures when working with batteries to prevent hazards like sparks and acid exposure.

Installation Guidelines

Recommendations for inverter installation location and conditions to ensure safe and optimal operation.

DC WIRING AND PARALLEL CONFIGURATION

DC Input Terminals and Wiring

Instructions for connecting DC power to the inverter, including terminal identification and cable requirements.

Parallel Mode Setup and Usage

Steps to configure the inverter for parallel operation and manage multiple units.

Parallel Wiring Diagrams

Visual guides illustrating how to wire multiple inverters for parallel operation.

RS-232 COMMANDS AND TROUBLESHOOTING

RS-232 Command Interface

Details on using the RS-232 port for communication, monitoring, and control via computer.

Troubleshooting Common Issues

Guidance on diagnosing and resolving common problems and error indicators.

WARRANTY INFORMATION

FUNCTIONAL CHARACTERISTICS AND APPLICATIONS

General Information and Features

Overview of the ECB series inverter's capabilities, design features, and applications.

Product Application Examples

Specific examples of where the ECB series inverters can be utilized, from tools to vehicles.

ELECTRICAL PERFORMANCE SPECIFICATIONS

ECB2500 Specification Details

Detailed technical specifications for the ECB2500 model, including voltage, power, and efficiency.

PRODUCT SPECIFICATIONS AND STANDARDS

Environment, Safety, and EMC

Operating environment limits, safety certifications, and electromagnetic compatibility standards.

Control Signals and Indicators

Information on LED indicators, remote control functions, and communication ports.

Physical and Communication Specs

Details on unit dimensions, weight, cooling method, and communication interfaces.

MECHANICAL DRAWINGS AND TRANSFER TIMES

Mechanical Drawings and Dimensions

Illustrations showing the physical layout and dimensions of the ECB series inverters.

Transfer Switch Time Tables

Data on the switching times for different transfer modes (ATS and STS).

INTRODUCTION AND PANEL OVERVIEW

Front and Rear Panel Layout

Diagrams identifying components and ports on the front and rear panels of the ECB series.

CONTROL PANEL AND INDICATORS

Power Switch and LED Status Indicators

Explanation of the main power switch and the meaning of different LED indicator states.

DIP SWITCH CONFIGURATION

DIP Switch Assignments (S1-S8)

Detailed mapping of DIP switch positions to inverter functions and settings.

Power Saving Mode Settings

Configuration options for enabling and adjusting the inverter's power saving mode.

ADVANCED DIP SWITCH FUNCTIONS

Parallel Application Setup (S4-S6)

Using DIP switches S4-S6 to configure settings for parallel operation, including phase relationships.

Parameter Selection (S8)

Using DIP switch S8 to select between LCM or DIP switch for parameter adjustment.

INPUT;OUTPUT PORTS AND CONNECTIONS

DC Inputs, Chassis Ground, Reset Button

Details on DC input terminals, chassis ground connection, and the reset button function.

AC Input;Output, Circuit Breaker, CAN Ports

Information on AC connections, input circuit breaker, and CAN communication ports for parallel operation.

LCM REMOTE CONTROL PORT

LCM Port Connection and Function

How to connect and use the LCD remote control panel for monitoring and setting ECB series inverters.

GREEN TERMINAL AND RS-232 INTERFACE

Green Terminal Functions (Remote;Parallel)

Using the green terminal for remote control and parallel connection selection.

RS-232 Port Connection Details

Wiring and connection specifics for the RS-232 serial communication port.

VENTILATION AND PROTECTION FEATURES

Fan Ventilation Requirements

Guidelines for maintaining adequate airflow around the inverter for proper cooling.

Input Protection Features

Details on the inverter's protective functions against over/under voltage and reverse polarity.

DC WIRING GUIDELINES AND FUSE SELECTION

Recommended DC Cable Size and Fuse Ratings

Guidance on selecting appropriate DC cable AWG and inline fuse ratings for ECB series.

DC INPUT VOLTAGE RANGES

ECB Series DC Input Voltage Ranges

Table showing the minimum and maximum DC input voltage limits for different ECB models.

HARD-WIRE INSTALLATION - GENERAL MODEL

General Model AC Wiring Steps

Step-by-step guide for hard-wiring the AC connections on the general model.

HARD-WIRE INSTALLATION - UL MODEL

UL Model AC Wiring Steps

Step-by-step guide for hard-wiring the AC connections on the UL model.

AC WIRING TERMINALS AND GAUGES

AC Output and Input Wiring Specifications

Details on wire colors, lengths, and gauges for AC output and input connections.

AC OUTPUT SOCKET OPTIONS

Available AC Output Socket Types

Overview of different AC output socket types supported by the ECB series.

PARALLEL MODE OPERATION AND SETUP

Preparing for Parallel Usage

Initial steps and requirements before setting up the inverters for parallel operation.

INDUSTRY APPLICATION TYPES

1Ø2 W, 1Ø3 W, 3Ø4 W Applications

Description of how ECB series inverters can be configured for different industrial power systems.

PARALLEL WIRING METHODS AND DIAGRAMS

Connection Methods and Diagrams

Detailed connection methods and diagrams for parallel inverter configurations.

AC WIRING DIAGRAMS OVERVIEW

1Ø2 W Wiring Diagram

Diagram illustrating the AC wiring for a single-phase, two-wire system.

AC WIRING DIAGRAMS - AUTO MASTER

1Ø2 W Auto Master Wiring Diagram

Wiring diagram for a 1Ø2W system using the auto master configuration.

AC WIRING DIAGRAMS - PARALLEL CONFIGURATIONS

1Ø2 W Parallel AC Wiring Diagram

Diagram showing the AC wiring for parallel operation in a 1Ø2W system.

AC WIRING DIAGRAMS - PHASE CONFIGURATIONS

1Ø3 W Parallel AC Wiring Diagram

Diagram illustrating the AC wiring for parallel operation in a single-phase, three-wire system.

AC WIRING DIAGRAMS - PHASE CONFIGURATIONS

3Ø4 W Parallel AC Wiring Diagram

Diagram showing the AC wiring for parallel operation in a three-phase, four-wire system.

PARALLEL CONNECTION REMOTE CONTROL

RS-232 Remote Setting

Steps for setting up remote control for parallel inverter operation using RS-232.

REMOVING PARALLEL CONNECTIONS

Procedure for Disconnecting Parallel Units

Steps to safely disconnect inverters that are configured for parallel operation.

RS-232 COMMAND SYSTEM

Command Introduction and Format

Overview of the RS-232 command structure, format, and response strings.

Setup Menu Commands

List of commands used to access setup menus and adjust inverter parameters.

RS-232 SETTING INTERFACE

Over Voltage Protection (OVP) Settings

Configuring the over-voltage protection thresholds and shutdown behavior.

OVP Recovery Settings

Setting the voltage levels at which the inverter will automatically restart after an OVP event.

VOLTAGE PROTECTION AND ALARM SETTINGS

Under Voltage Protection (UVP) Settings

Configuring the under-voltage protection thresholds and shutdown behavior.

UVP Recovery Settings

Setting the voltage levels for automatic restart after a UVP event.

UV Alarm Configuration

Setting up audible alerts for low input voltage conditions.

OUTPUT AND FREQUENCY CONFIGURATION

Output Voltage Settings

Selecting and configuring the output voltage for the inverter operation.

RS-232 Baud Rate Selection

Setting the communication speed for the RS-232 serial interface.

Output Frequency Settings

Configuring the output frequency of the inverter.

Sync Frequency Settings

Adjusting frequency synchronization parameters for grid or generator input.

ALARM, SAVING AND INTERVAL SETTINGS

Overload Alarm Configuration

Setting overload alarm thresholds and associated relay actions.

Shut-down Retry Settings

Configuring the number of automatic retries after protective shutdowns.

Saving Level and Interval

Adjusting power saving levels and the interval for load detection.

BYPASS, LCD AND BUZZER SETTINGS

Bypass Relay Configuration

Setting the bypass relay behavior for different operating modes (online/offline).

LCD Contrast and Auto-off

Adjusting LCD screen contrast and backlight auto-off timer settings.

Buzzer Settings

Configuring buzzer sounds for different events like alerts, shutdowns, and messages.

ALERT AND LANGUAGE OPTIONS

Alert Settings

Configuring how alerts are signaled via dry contact relay and LCD display.

Language Selection

Choosing the display language for the inverter's interface.

TROUBLESHOOTING AND WARRANTY

Troubleshooting Guide

A guide to identify and resolve common problems with the ECB series inverter.

Product Warranty Details

Information on the warranty period, coverage, and conditions for voiding the warranty.

EZA ECB Series Specifications

General IconGeneral
THD<3%
Input Voltage12V/24V/48V DC
Output Frequency50Hz / 60Hz
CoolingFan
ProtectionOver Load, Short Circuit, Over Temperature

Related product manuals