Installation manual
CNC 8035
MACHINE PARAMETERS
General machine parameters
4.
(SOFT M: V15.3X)
(S
OFT T: V16.3X)
·107·
PROBEDEF (P168)
Defines the behavior of the probe.
This parameter has 16 bits counted from right to left.
Each bit has a function or work mode associated with it. By default, all the bits will be assigned the
value of ·0·. Assigning the value of ·1· activates the corresponding function.
Bit 0. Smooth stop of the probe (G75/G76).
This bit permits defining a smooth stop for probing moves (bit=1). When the probe pulse is detected,
the following error is not reset, thus making the probe stop more smoothly.
When setting the smooth stop, a.m.p "DERGAIN (P25)" and s.m.p. "FFGAIN (P25)" should be set
to zero. This may be done by setting the set of gains through g.m.p. "ACTGAIN2 (P108)" with the
bit corresponding to G75/G76.
CANSPEED (P169)
CAN bus transmission speed for the digital drives.
The transmission speed depends on the length of the cable or total CAN connection distance.
FEEDTYPE (P170)
Behavior of the feedrate when programming F0.
If set to 0, F0 may be programmed and the motion blocks will be executed at the maximum feedrate
allowed.
If set to 0, it is not possible to program F0 or execute motion blocks with F0 active.
Bit Meaning
0 Smooth stop of the probe.
1 - 15 Not being used.
Default value in all the bits: 0
bit
15
14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Value Meaning
0 1 Mbit/s. Maximum distance: 20 meters.
1 800 kbit/s. Maximum distance: 45 meters.
2 500 kbit/s. Maximum distance: 95 meters.
Default value: 0 (1 Mbit/s)
Value Meaning
0 Movement at maximum feedrate possible.
1 F0 cannot be programmed.
Default value: 0