Installation manual
CNC 8035
MACHINE PARAMETERS
General machine parameters
4.
(SOFT M: V15.3X)
(S
OFT T: V16.3X)
·87·
USERMAN (P49)
Indicates the number of the user program associated with the JOG mode. This program will be
executed via the user channel when pressing the softkey USER in the JOG mode.
USERDIAG (P50)
Indicates the number of the user program associated with the Diagnosis mode. This program will
be executed via the user channel when pressing the softkey USER in the DIAGNOSIS mode.
ROPARMIN (P51) ROPARMAX (P52)
They indicate the upper limit "ROPARMAX " and lower limit "ROPARMIN" of the global arithmetic
parameter group (P100-P299), user arithmetic parameters (P1000-P1255) or OEM arithmetic
parameters (P2000-P2255) to be write-protected. There are no restrictions to read these
parameters.
The parameters write-protected from the CNC may be modified from the PLC.
PAGESMEM (P53) NPCROSS2 (P54) MOVAXIS2 (P55)
COMAXIS2 (P56) NPCROSS3 (P57) MOVAXIS3 (P58)
COMAXIS3 (P59)
Not being used.
TOOLSUB (P60)
Indicates the number of the subroutine associated with the tools. This subroutine will be executed
automatically every time a T function is executed.
CYCATC (P61)
This parameter must be used when having a machining center, g.m.p. TOFFM06 (P28) = YES.
Indicates whether a cyclic tool changer is being used or not.
A "cyclic tool changer" is an automatic tool changer which requires an M06 command (tool change)
after searching for a tool and before searching for the next one.
With a non-cyclic tool changer, it is possible to search for several tools in a row without necessarily
having to make the actual tool change (M06 function).
Possible values
Integer numbers between 0 and 65535.
Default value: 0 (none)
Possible values
Integer numbers between 0 and 65535.
Default value: 0 (none)
Possible values
Integer numbers between 0 and 9999.
Default value: 0 (it is not protected)
Possible values
Integer numbers between 0 and 9999.
Default value: 0 (none)
Value Meaning
YES It is a cyclic changer.
NO It is not a cyclic changer.
Default value: YES