Installation manual
CNC 8035
MACHINE PARAMETERS
General machine parameters
4.
(SOFT M: V15.3X)
(S
OFT T: V16.3X)
·95·
XFORM (P93) XFORM1 (P94) XFORM2 (P95)
Not being used.
XDATA0 (P96) XDATA1 (P97) XDATA2 (P98) XDATA3 (P99)
XDATA4 (P100) XDATA5 (P101) XDATA6 (P102) XDATA7 (P103)
XDATA8 (P104) XDATA9 (P105)
Not being used.
PRODEL (P106)
The CNC takes this parameter into account when probing, functions G75 and G76.
When the digital probe communicates with the CNC via infrared beams, there could be some delay
(milliseconds) from the time the probe touches the part to the instant the CNC receives the probe
signal.
The probe keeps moving until the CNC receives the probe signal.
Parameter PRODEL indicates, in milliseconds, the delay mentioned earlier.
While probing, the CNC always takes into account the value assigned to parameter PRODEL and
provides the following information (variables associated with the coordinates).
TPOS Actual position of the probe when the CNC receives the probe signal.
DPOS Theoretical position of the probe when the probe touched the part.
With "PRODEL=0", the DPOS variable has the same value as the TPOS variable.
MAINOFFS (P107)
Indicates whether the CNC maintains the tool offset number (D) on power-up and after an
EMERGENCY or RESET.
ACTGAIN2 (P108)
The axes and the spindle can have 3 sets of gains and accelerations. By default, the CNC always
assumes the first set indicated by the parameters of the axis or of the spindle ACCTIME, PROGAIN,
DERGAIN and FFGAIN.
Parameter ACTGAIN2 indicates when the CNC assumes the second set of gains and accelerations,
indicated by the parameters of the axis or of the spindle ACCTIME2, PROGAIN2, DERGAIN2 and
FFGAIN2.
Possible values
Integer numbers between 0 and 255.
Default value: 0
Value Meaning
0 It does not maintain it. It always assumes offset D0.
1 It maintains it.
Default value: 0