ACSD-58/80 Digital Brushless AC Servo Drive system - Ref.1609
K. Monitoring
Function Contains the value of power of the external ballast resistor.
Valid values 200 ... 2 000 W.
Default value 200 W.
Function Contains the value of the energy pulse that can be
dissipated by the external ballast resistor.
Valid values 200 ... 2 000 J.
Default value 200 J.
Function Motor temperature in degrees centigrade (for the time
being, it is now only valid for the FKM family).
Valid values 0 ... 200 °C.
Function It displays the temperature of the heatsink of the power
stage.
Valid values 0 ... 200 °C.
Function Variable internally useful to the system. It measures the
internal load level of the calculation of the i²t at the drive in
percentage used over the maximum.
Valid values 0 ... 100 %.
Function Variable internally useful to the system. It measures the
internal load level of the calculation of the i²t at the motor in
percentage used over the maximum.
Valid values 0 ... 100 %.
Function Shows the load percentage on the ballast resistor in a drive.
Useful for the i²t protection of the resistor. A value greater
than 100 % in this variable causes error E.314.
Valid values 0 ... 100 %.
Function Selector that determines whether the Ballast resistor is
external or internal.
Valid values 0/1 External/internal.
KP3 USER, RW S33882 ExtBallastPower
KP4 USER, RW S33884 ExtBallastEnergyPulse
KV6 BASIC, RO S00383 MotorTemperature
KV10 USER, RO S33870 CoolingTemperature
KV32 USER, RO S33877 I2tDrive
KV36 USER, RO S33879 I2tMotor
KV40 USER, RO S33883 I2tCrowbar
KV41 USER, RW S33885 BallastSelect