TST Assembly instructions FUF2 / FU3F -A/-C/-F
FEIG ELECTRONIC GmbH page 93 of 114 TST_FUxF-A-C-F_Montageanleitung_EN_15
Possible reason for error
Testing incorrect for output 1 of the stationary unit
• Output 1 of the stationary unit was tested as faulty
• The cable between the stationary unit and the controller is damaged or not
connected
• The stationary unit is defective
• Incorrect settings for parameter P.5xF, P.47b or P.465
Testing incorrect for output 2 of stationary unit
• Output 2 of the stationary unit was tested incorrectly
• The cable between stationary unit and controller is damaged or not
connected
• The stationary unit is defective
• Incorrect settings for parameter P.5xF, P.47b or P.465
Testing incorrect for output 3 of the stationary unit
• Output 3 of the stationary unit was tested incorrectly
• The cable between the stationary unit and the controller is damaged or not
connected
• The stationary unit is defective
• Incorrect settings of parameter P.5xF, P.47b or P.465
Wrong parameter setting input 1 of mobile unit
• The device which is connected to input 1 of the mobile unit does not fit to the
settings
• Check Parameter P.F1F
Wrong parameter setting input 2 of mobile unit
• The device which is connected to input 2 of the mobile unit does not fit to the
settings
• Check Parameter P.F2F
Wrong parameter setting input 3 of mobile unit
• The device which is connected to input 3 of the mobile unit does not fit to the
settings
• Check Parameter P.F3F
Wrong parameter setting input 4 of mobile unit
• The device which is connected to input 4 of the mobile unit does not fit to the
settings
• Check Parameter P.F4F
Disturbed input 1 of mobile unit TST FSx
• The input 1 of the mobile unit is disturbed
• The connection to the device is interrupted
Disturbed input 2 of mobile unit TST FSx
• The input 2 of the mobile unit is disturbed
• The connection to the device is interrupted
Disturbed input 3 of mobile unit TST FSx
• The input 3 of the mobile unit is disturbed
• The connection to the device is interrupted
Disturbed input 4 of mobile unit TST FSx
• The input 4 of the mobile unit is disturbed
• The connection to the device is interrupted
Frequency error on input 1 of mobile unit
• The connected optical safety edge is faulty