FEIG ELECTRONIC GmbH page 93 of 114 TST_FUxF-A-C-F_Montageanleitung_EN_15
No.
Description
Possible reason for error
F.811
Testing incorrect for output 1 of the stationary unit
• Output 1 of the stationary unit was tested as faulty
• The cable between the stationary unit and the controller is damaged or not
connected
• The stationary unit is defective
• Incorrect settings for parameter P.5xF, P.47b or P.465
F.812
Testing incorrect for output 2 of stationary unit
• Output 2 of the stationary unit was tested incorrectly
• The cable between stationary unit and controller is damaged or not
connected
• The stationary unit is defective
• Incorrect settings for parameter P.5xF, P.47b or P.465
F.813
Testing incorrect for output 3 of the stationary unit
• Output 3 of the stationary unit was tested incorrectly
• The cable between the stationary unit and the controller is damaged or not
connected
• The stationary unit is defective
• Incorrect settings of parameter P.5xF, P.47b or P.465
F.821
Wrong parameter setting input 1 of mobile unit
• The device which is connected to input 1 of the mobile unit does not fit to the
settings
• Check Parameter P.F1F
F.822
Wrong parameter setting input 2 of mobile unit
• The device which is connected to input 2 of the mobile unit does not fit to the
settings
Check Parameter P.F2F
F.823
Wrong parameter setting input 3 of mobile unit
• The device which is connected to input 3 of the mobile unit does not fit to the
settings
• Check Parameter P.F3F
F.824
Wrong parameter setting input 4 of mobile unit
• The device which is connected to input 4 of the mobile unit does not fit to the
settings
• Check Parameter P.F4F
F.831
Disturbed input 1 of mobile unit TST FSx
• The input 1 of the mobile unit is disturbed
• The connection to the device is interrupted
F.832
Disturbed input 2 of mobile unit TST FSx
• The input 2 of the mobile unit is disturbed
• The connection to the device is interrupted
F.833
Disturbed input 3 of mobile unit TST FSx
• The input 3 of the mobile unit is disturbed
• The connection to the device is interrupted
F.834
Disturbed input 4 of mobile unit TST FSx
• The input 4 of the mobile unit is disturbed
• The connection to the device is interrupted
F.841
Frequency error on input 1 of mobile unit
• The connected optical safety edge is faulty

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Feig Electronic TST FUF2-C and is the answer not in the manual?

Feig Electronic TST FUF2-C Specifications

General IconGeneral
BrandFeig Electronic
ModelTST FUF2-C
CategoryController
LanguageEnglish

Related product manuals