TST Assembly instructions FUF2 / FU3F -A/-C/-F
FEIG ELECTRONIC GmbH page 100 of 114 TST_FUxF-A-C-F_Montageanleitung_EN_15
The Paramterfile can not be loaded because it`s forbidden
The Paramterfile can not be loaded because the file is incompatible
The Paramterfile can not be loaded because there is min. one not writeable parameter included
The Paramterfile can not be loaded because the content is invalid
The Paramterfile can not be loaded because of an unknown problem
There is a new or unconfigured device on the CAN or RS485 bus.
Poor CAN bus quality during the teach-in process:
•bad CAN BUS wiring
•no ferrite cores on the motor cable
•Incorrect CAN bus termination (missing or wrongly placed termination resistors)
•Too long CAN bus lines (>180m)
•faults on the CAN line when the door operator is moving
possible improvement:
• Ferrite core around the CAN cabling within the control unit
The customer coding of the VEK MNST was successfully completed.
The customer coding of the MWD BPC Sensor 1 was successfully completed.
The customer coding of the MWD BPC Sensor 2 was successfully completed.
The customer coding of the MWD BPC Sensor 3 was successfully completed.
The customer coding of the MWD BPC Sensor 4 was successfully completed.