FEIG ELECTRONIC GmbH Page 88 of 96 TST_FUZ2-A-B-C-CX-G-L_Montageanleitung_EN_22.docx
Possible reason for error
Converter parameters not
plausible
• New EPROM version
• Controller not yet initialized
Program version / manufacturer
code
• New EPROM version
• Controller not yet initialized
Faulty door cycle counter with
active emergency opening
• The door cycle counter does not count or is faulty. Because of this no emergency opening testing can be done.
• A wrong software was programmed to the controller
• The programmed software does not recognize the hardware version
• The controller hardware is defective
Incompatible TST LGB software
version
TST LGB with software version V3.21 or earlier in combination with DES-A connected and activated.
Programming error with Real
time clock
• The clock is not programmed plausible
Internal real time clock error
• The clock has an error → make a reset
Plausibility parameter block
error
• New EPROM version
• Controller not yet initialized
• Some parameter is implausible