B. Summary of components
B−11
Festo P.BE−CPV−EN en 0503g
End plate pairs for internal auxiliary pilot air
(internal pilot air), with pneumatic connections
Description
CPV..−EPL−G CPV..−EPR−E
Ident. code: −−−
Connections in left and right−hand
end plates
Pressure zone separation
permitted
Maximum number of pressure
zones 3
Valves to the right of the separator
plate can be used for vacuum
Connection 12/14 in the right−
hand end plate must be sealed
with a blind plug.
· Connections, which are not
required for the function of the
valve terminal, must be sealed
(see also section 3.3.2 Connect
ing the supply and work tubing).
CPV..−EPL−G CPV..−EPR−G
Ident. code: −−−
Connections in left and right−hand
end plates
Pressure zone separation only
permitted with separator plate
Ident.code S for exhaust separ
ation.
Maximum number of pressure
zones 1
Cannot be used for vacuum
Tab.B/7: End plates for internal auxiliary pilot air