3. Installation
3−20
Festo P.BE−CPV−EN en 0503g
Connect the valve solenoid coils as follows:
· Use connector socket KMYZ−7−... (CPV10/14) or
KMEB−2−... (CPV18). Connector socket KMYZ−7−... is fitted
with current reduction.
· Insert the socket onto the terminal lugs of the appropriate
pilot solenoid (see diagram). The socket can also be fitted
turned 180°. Make sure that the centring bolt between
the terminal lugs grips into the hole in the socket. Screw
the socket together with the central locking screw with
0.15Nm.
Fig.3/7: Fitting the individual connecting sockets