5. Maintenance and conversion
5−23
Festo P.BE−VTSA−44−EN en 0509NH
Fitting Proceed as follows:
1. Fit the new manifold block and, if applicable, a further
pneumatic supply plate (see section 5.3.4).
2. Fit the relevant components, e.g. vertical stacking compo
nents, valves or cover plates onto the empty valve loca
tions (see section 5.3.2 for fitting vertical stacking compo
nents and section 5.3.4 for fitting valves or
cover plates).
3. Fit the valve terminal onto the fastening surface (see
chapter 2 Fitting, Fitting onto a wall" or Fitting onto a
hat rail").
4. Then complete the pneumatic and electrical connections
(see chapter 3 Installation, Connecting the VTSA valve
terminal").