5 ESD Characteristics
The module is generally not protected against Electrostatic Discharge (ESD). ESD handling precautions
that apply to ESD sensitive components should be strictly followed. Proper ESD handling procedures
must be applied throughout the processing, handling, assembly and operation of any application with
module. The ESD characteristics are shown in the following table (Temperature: 25°C, Relative Humidity:
40%).
Interface
Contact Discharge
Air Discharge
GND
±8 kV
±15 kV
Antenna Interface
±8 kV
NA
Golden Finger
±2 kV
NA
Note
ESD performance is based on EVB-M2 development board.