5-37
Advanced Menu
The Advanced Menu can be reached
from the “operator menu” by accessing
the “password” parameter and setting
the value 60.
Change a Parameter (in the Advanced
Menu)
To change the value of a parameter, pro-
ceed as follows:
• Scroll through the submenus with
the buttons “3” and “4”.
• Select the submenu that contains
the parameters to be changed using
the button “2”.
• Scroll through the parameters with
the buttons “3” and “4” to find the
parameter to be edited.
• Select the parameter with the button
“2”.
• Use the buttons “3” and “4” to scroll
through the list of available values of
the parameter.
• Confirm the new value of the param-
eter using the button “2”.
• To enable the changes, it is neces-
sary to return to the “menu work”;
to exit the parameters and return to
the “Advanced Menu” press simul-
taneously the buttons “3” and “4”,
then find the sub-menu “Exit” and
confirm with button “2”.
Check/Monitor Function
It is possible to view all the values of the
Check/monitor function during the nor-
mal work of the machine. To view the
values, following the instruction:
• Turn OFF the machine
• Press in the same time, the buttons
“2”, “3” and “4”
• Until the buttons are pressed, turn
ON the key and wait the upload of
the “working menu”
• Use the buttons “3” or “4” to select
the submenu “password”
• Confirm pressing button “2”
• Press button “3” or “4” until to select
the password “60”
• Confirm the password by pressing
the button “2” to enter into the “ad-
vanced menu”
• Press the button “3” or “4” to select
the menu “Check/Monitor”
• Confirm by pressing the button “2”
• Press the button “3” or “4” to se-
lect the parameter you want to check
during normal work.
• Press the button “2” to confirm
• After confirmed, the display will re-
turn to normal view, but instead of
the battery control card it will be dis-
played the values of the selected pa-
rameters.
• By pressing the button “2” it is pos-
sible to check the parameters of the
Check/Monitor submenu
• To exit form the “Check/Monitor”
view, turn OFF and ON the machine.