Confirm with the button . The display will start flashing the actual Temperature Setpoint
. This can be modified using buttons or , with increments of 0.1°C.
Confirm by pressing the button . The display will show a message asking to confirm or to exit from the Menu
with the message .
Confirm again with the button . The display will show the message and the controller
will start adjustment with the new temperature setpoint value.
Instead, press the button to cancel the operation and go back to main menu.
4.2.3.3 Manual defrost function
Fiocchetti cabinets are equipped with automatic, intelligent defrosting, or rather defrosting which only occurs if deemed
necessary by the controller. The number of daily defrosts is therefore significantly reduced, resulting in considerable
energy savings.
However, it may sometimes be necessary to perform manual defrosting. This function is enabled by following the
procedure below.
Press the button and by using the buttons or stops at the string
Confirm by pressing the button . The display will show a message asking to confirm or to exit from the Menu
with the message .
Confirm again with . The controller acquires the defrosting order and the display shows the message
.
If manual defrost cannot be enabled until the conditions required for its implementation are detected, the display will
show the message .
If defrost is delayed by the controller due to certain pre-set managing parameters, the display will show the message
.
At the end of defrost, the phases and will proceed until the next
setpoint is reached.
4.2.3.4 Recorded alarms log
The controller signals four types of temperature alarm and records the last 16 events in the corresponding
.