17. Warnings and error messages
To enable the safe operation of the generator, the Panda iControl2 controller is programmed with a series of
warnings and error messages that influence the generator operation.
17.1 Warnings
Warnings are issued when the variable being monitored, e.g. temperature, reaches a defined warning threshold.
The warnings are issued on the Panda iControl2 panel display via the cyclical display of the word „HIGH“ or „LOW“,
alternating with the measured value, e.g. the temperature. Warnings do not become active until the time between
reaching the threshold value and the defined delay has expired.
Note:Warnings do not result in the generator or the controller
being switched off.
17.1.1 Examples of warnings on the display:
Fig. 17.1.1-1: Warning: „Battery power too low“Warning: „Battery power too low“
Fig. 17.1.1-2: Warning: „Winding temperature too high“Warning: „Winding temperature too high“