General operation
Seite/Page 138 - Kaptitel/Chapter 13: General operation 14.7.16
Fig. 13.3.3.4-7: Phase voltage L3This screen provides the latest inverter output voltage of the
single phases with the matching conductor current and the
circuit board temperature. The inverter will be switched off at
a circuit board temperature of 75 °C. You can access the
inverter screen by actuating the cursor-up button while in
operation mode.
13.3.3.5 Panda i-Generator with electro-magnet Clutch (optional)
Attention!: During the activation of the electro-magnetic clutch, the
icontrol raise the generator speed to maximum.
After the clutch is released, the generator speed will drop to normal.