Appendix Multi-DENCO
136 FläktGroup DC-2013-0101-GB • Subject to modifications • R5-08/2020
Multi -DENCO
®
Commissioning Record
A-Version
°C °C
°C °C
% RH % RH
% RH % RH
Yes/No %
Yes/No %
bar bar
bar bar
bar bar
Yes/No Fans free from vibration at all speeds Yes/No
V
m
3
/s
V
m
3
/s
V
m
3
/s
Yes/No mbar
Air distribution to space checked Yes/No
bar Torr
m m
kg tonnes
litres Number
Yes/No
Yes/No
% %
°C °C
°C °C
RPS RPS
bar bar
bar bar
Suction Pipe Temperature °C Suction Pipe Temperature °C
Suction Superheat K Suction Superheat K
EEV Position
%
EEV Position
%
Discharge Pipe Temperature °C Discharge Pipe Temperature °C
Discharge Superheat K Discharge Superheat K
°C °C
K K
A A
A A
Condenser Fan Motor Current A Condenser Fan Motor Current A
Mech HP Switch functions? Yes/No bar
Grn/Yel Yes/No
Yes/No
Int/Ext/No A
A A
Discharge Pressure
Total Pipework Rise
Oil Traps Fitted
Mech HP Trip Value
Option Fitted?
Verify Transducer & Sensor Calibration
Winter Kit EEV Control Settings Checked
Compressor 1 Current
Compressor 2 Current
Compressor 1 Current
Sub-cooling
Vacuum Achieved
Weight of Refrigerant R410A
Dehum Fan Speed
L.P. Envelope Threshold L.P. Alarm Threshold
Pressure Strength Test Value
Filter Switch Setting
Thyristor Control Fitted Heater Bank 2 Current L2
Heater Bank 1 Current L1
Sub-cooling
Liquid Line TemperatureLiquid Line Temperature
Suction Pressure Suction Pressure
EEV Moisture Indication
Heater Bank 3 Current L3
Electric Heating
Refrigeration Circuit
Refrigeration Operating Conditions
Compressor speed Compressor speed
CO
2
equivalent
Discharge Pressure
Circuit Pipe Length
Fan motor currents checked
Condenser Fan Differential
Dehum Interlock Enabled
Humidity Dead Zone
H.P. Envelope Threshold
Heating Dead Zone
Dehum Enabled
Condenser Fan Set Point
Dehum Proportional Band
Cooling Proportional Band
Dehum Dead Zone
Dehum Cooling Assigned
Heating Proportional Band
Cooling Dead Zone
Compressor 2 Current
Refrigeration Operational Checks
H.P. Alarm Threshold
Optical oil sensor function check
(
092
&130 only)
Max Fan Speed Setting
Min Fan Speed Setting
Fan Check List
Humidity Proportional Band
Dehum Cool Demand
Oil Added To Circuit
Winter Kit Fitted?
Air Off Temperature Air Off Temperature
Cooling Demand Cooling Demand
Air On Temperature Air On Temperature
Air Flow Fail Check
Controls - Continued
Design Air Flow
Max Measured Air Volume
Min Measured Air Volume
Page 3 of 4
Based on DQA800