FLUXUS F70x A Menu Structure
180 UMFLUXUS_F7V4-6-2EN, 2017-10-01
input of the kinematic viscosity of the medium
input of the operating density of the medium
confirmation that the changes are to be stored
This display will only be indicated if a new medium has been entered or the
properties of an existing medium have been changed.
Special Funct.\SYSTEM settings\Remote inputs
selection of the menu item for the remote functions x
selection of the channel for which the remote function is to be configured x
selection of the method for the configuration or deactivation of the remote func-
tion of the selected channel
x
The actual measured flow velocity will be ignored and the measured value will
be set to 0.
x
The totalizers are reset to 0. The totalizers are deactivated for the duration of the
switching signal.
x
If the totalizers are reset to 0 with using the remote function, a downward arrow
will be displayed next to the value of the totalizer during the measurement.
x
The totalizers are stopped for the duration of the switching signal. x
The FastFood mode is activated for the duration of the switching signal. x
stop of the editing of the remote function x
selection of the binary input which is to be used to trigger the previously selected
remote function (here:
clear totals
)
x
selection of the channel from which the remote function configuration is to be cop-
ied to the currently selected channel
x
selection for the reset of the remote function x
After the Input of HotCode 071001
input of the lower limit of the inner pipe diameter for the displayed transducer
type
range: 3...63 mm
x
INIT-
resistant
VISCOSITY
1.0 mm2/s
DENSITY
1.0 g/cm3
Save changes
no >YES<
SYSTEM settings
Remote inputs
Remote inputs
for Channel
Remote inputs
A: Edit...
A: Remote-Func.
Signal Lock
A: Remote-Func.
clear totals
A: +0.000 l
88.79 l/h
A: Remote-Func.
No totalizing
A: Remote-Func.
FastFoodMode
A: Remote-Func.
go back
A: clear totals
Binary Input S1
A: Copy from
Channel B:
Remote inputs
A: Clear all
DNmin Q-Sensor
15 mm

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Flexim FLUXUS F705**-NN Series and is the answer not in the manual?

Flexim FLUXUS F705**-NN Series Specifications

General IconGeneral
BrandFlexim
ModelFLUXUS F705**-NN Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals