210 UMFLUXUS_G6V4-2EN, 2011-03-29
FLUXUS G60x B Technical Data
explosion protection
A
T
E
X
transducer GSM-EA2NL GSP-EA2NL
category
EPL
zone
gas: 3G dust: 2D
Gc Db
2 21
gas: 3G dust: 2D
Gc Db
2 21
explosion protection temperature (pipe surface)
min. °C -45 -45
max. °C +235 +235
marking
0637
II3G Ex nA IIC T6...T2 Gc X
II2D Ex tb IIIA TX Db
0637
II3G Ex nA IIC T6...T2 Gc X
II2D Ex tb IIIA TX Db
certification IBExU10ATEX1163 X IBExU10ATEX1163 X
type of protection gas: non sparking
dust: protection by enclo-
sure
gas: non sparking
dust: protection by enclo-
sure
necessary trans-
ducer mounting
fixture
--
1
depending on application, typical absolute value for natural gas, nitrogen, compressed air
2
shear wave transducer:
typical values for natural gas, nitrogen, oxygen, pipe diameters for other gases on request
pipe diameter min. recommended/max. recommended/max. extended: in diagonal mode and for a
flow velocity of 15 m/s
technical type GDM2EH5 GDP2EH5