6 Mounting
6.2 Transducers FLUXUS G801
2020-06-26, UMFLUXUS_G801V1-0EN
54
• Position the ratchet clasp, tension strap clamp and metal spring (if necessary) on the pipe:
– on a horizontal pipe, mount the tension strap clamp laterally to the pipe, if possible
– mount the metal spring (if necessary) opposite to the tension strap clamp
• Insert the long end of the tension strap into the slot of the tension strap screw (see Fig. 6.46).
• Tighten the tension strap.
• Cut off the protruding tension strap (see Fig. 6.46).
• Tighten the screw of the ratchet clasp.
• Repeat the steps for the second tension strap.
• Put the rail on the tension strap clamps (see Fig. 6.47).
• Fix the rail to the tension strap clamps with the screws.
• Tighten the screws.
Notice!
In order to release the screw and the tension strap, press the lever down (see Fig. 6.46).
Fig. 6.45: Ratchet clasp with tension strap, clamp and metal spring on the pipe
1 – metal spring
2 – ratchet clasp
3 – tension strap clamp
Fig. 6.46: Ratchet clasp with tension strap
1 – sense of rotation
2 – edge
3 – lever
4 – clasp screw with slot
Fig. 6.47: Rail on the pipe
1 – screws
21 3
1
2
4
3
4
1 1