FLI R Duo User Guide
436-0100-01-10, Rev. 200 Duo User Guide
Information on this page is subject to change without notice
95
In CSP-TCP applications, the CRC is ignored
4.4 Recording or capturing stop notification
Request instruction
Instruction Application: UART /
TCP
Data flow: CS --- G / A
Identification
code
1 Byte
status code
1 Byte
Instruction number
2 Bytes
Instruction length
2 Bytes
CRC1
/ reserved
2 Bytes
0x64
0x00
0xE006
0x14
CRC
Instruction body
20 Bytes
CRC2
/ reserved
2 Bytes
Instruction body format:
Typedef struct {
Uint32_t u32ID;
} SendRecord Stop EventNotifyParam;
CRC
CRC Description :
In CSP-TCP applications, the CRC is ignored
4.5 Recording or capturing start notification
The device receives a video or capture instruction, confirms execution , and immediately invokes the event notification .
Request instruction
Instruction Application: UART /
TCP
Data flow: CS --- G / A
Identification
code
1 Byte
status code
1 Byte
Instruction number
2 Bytes
Instruction length
2 Bytes
CRC1
/ reserved
2 Bytes
0x64
0x00
0xE00 8
0x14
CRC
Instruction body
20 Bytes
CRC2
/ reserved
2 Bytes
Instruction body format:
Typedef struct {
Uint32_t u32ID;
CRC