FLI R Duo User Guide
436-0100-01-10, Rev. 200 Duo User Guide
Information on this page is subject to change without notice
66
In CSP-TCP applications, the CRC is ignored
3.10.2 settings
Request instruction
Instruction Application: UART /
TCP
Data flow: G / A --- CS
Identification
code
1 Byte
status code
1 Byte
Instruction number
2 Bytes
Instruction length
2 Bytes
CRC1
/ reserved
2 Bytes
0x64
0x00
0x101C
0x04
CRC
Instruction body
4 Bytes
CRC2
/ reserved
2 Bytes
Instruction body format:
Struct {
BOOL bEnable; 0- // Close 1- opening
Byte Reserve [3]; // Reserved
};
CRC
CRC Description :
In CSP-TCP applications, the CRC is ignored
Response command:
Instruction Application: UART /
TCP
Data flow: CS --- G / A
Identification
code
1 Byte
status code
1 Byte
Instruction number
2 Bytes
Instruction length
2 Bytes
CRC1
/ reserved
2 Bytes
0x64
Status Code
0x101D
0x00
CRC
Instruction body
0 Bytes
CRC2
/ reserved
2 Bytes
air
CRC
CRC Description :
In CSP-TCP applications, the CRC is ignored
3.11 TONES enabled

Table of Contents