FLI R Duo User Guide
436-0100-01-10, Rev. 200 Duo User Guide
Information on this page is subject to change without notice
74
Instruction Application: UART /
TCP
Data flow: G / A --- CS
Identification
code
1 Byte
status code
1 Byte
Instruction number
2 Bytes
Instruction length
2 Bytes
CRC1
/ reserved
2 Bytes
0x64
0x00
0x2000
0x08
CRC
Instruction body
8 Bytes
CRC2
/ reserved
2 Bytes
Instruction body format:
Struct {
U8i uint8_t , use the setting ; // capture interval, 0 ~ 60s ; 0- refers to a single
capture
Uint8_t u8Format; // file format, 0-RJPEG , 1-JPEG & TIFF
Byte Reserve [2]; // Reserved
ui nt32_t u32ID; // ID unique
};
CRC
CRC Description:
In CSP-TCP applications, the CRC is ignored
Response command:
Instruction Application: UART /
TCP
Data flow: CS --- G / A
Identification
code
1 Byte
status code
1 Byte
Instruction number
2 Bytes
Instruction length
2 Bytes
CRC1
/ reserved
2 Bytes
0x64
Status Code
0x2001
0x04
CRC
Instruction body
4 Bytes
CRC2
/ reserved
2 Bytes
Instruction body format:
Struct {
ui nt32_t u32ID; // ID unique
};
CRC