Example command: SYST:CONF:PDEV?
Example response: 1
6.5.8.17 SYSTem:CONFigure:PRINter[n]:DADDress?
This query command returns the device address (number of the device within
its module) of a given printer device. The printer device number is given by the
PRIN suffix n. Printer devices are assigned numbers sequentially starting with
1. The command SYST:CONF:PDEV? (Section 6.5.8.16) can be used to deter
-
mine the number of installed printer devices.
Example command: SYST:CONF:PRIN1:DADD?
Example response: 4
6.5.8.18 SYSTem:CONFigure: PRINter[n]:MADDress?
This query command returns the module number or address of the module that
contains a given printer device. The printer device number is given by the PRIN
suffix n. Printer devices are assigned numbers sequentially starting with 1. The
command SYST:CONF:PDEV? (Section 6.5.8.16) can be used to determine the
number of installed printer devices.
Example command: SYST:CONF:PRIN1:MADD?
Example response: 3
6.5.8.19 SYSTem:MODule[n]:DEVice[n]:READ? <device_command>
This query command is used to read configuration parameters directly from a
device. The device is specified by module number and device number. The
module and device numbers are given by the MOD suffix and DEV suffix re-
spectively. The command SYST:CONF:MNUM? (Section 6.5.8.8) can be used
to determine the number of installed modules and the command
SYST:CONF:MOD[n]:DNUM? (Section 6.5.8.10) can be used to determine the
number of devices within a module. The <device_command> parameter is the
command string (enclosed in quotes) passed to the device. Each device has a
unique set of commands (refer to the operating instructions for a specific mod
-
ule for a list of its device commands). The response type can be either a nu
-
meric value or character data depending on the device command.
Example command: SYST:MOD2:DEV1:READ? “CURR”
Example response:10
6.5.8.20 SYSTem:MODule[n]:DEVice[n]:WRITe <device_command>,<value>
This command can be used to directly send a command to a device to set a con
-
figuration parameter. The device is specified by module number and device
number. The module and device numbers are given by the MOD suffix and
DEV suffix respectively. The command SYST:CONF:MNUM? (Section
6.5.8.8) can be used to determine the number of installed modules and the com
-
mand SYST:CONF: MOD[n]:DNUM? (Section 6.5.8.10) can be used to deter
-
1560 Thermometer Readout
User’s Guide
98

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 1560 Black Stack and is the answer not in the manual?

Fluke 1560 Black Stack Specifications

General IconGeneral
BrandFluke
Model1560 Black Stack
CategoryThermometer
LanguageEnglish

Related product manuals