SELECT A DISPLAY FIELD
DISPLAY FIELD: 1
Next, a new window appears allowing you to select the data for the given field.
SELECT THE DATA FOR FIELD 1
+CHANNEL: 1
–CHANNEL: 0
CALCULATION: TEMP
CHANNEL 0=NONE
CHANNEL 99=ALL
+CHANNEL specifies the input channel for the positive component of the dif-
ference calculation. –CHANNEL specifies the input channel for the negative
component of the difference calculation. You may enter 0 to ignore that part of
the calculation or 99 to apply the most recent measurement regardless of chan
-
nel. Use the numeric buttons to enter a number and press ENTER.
CALCULATION specifies the type of calculation for which the results are dis
-
played. The options are given in Table 4 below. The calculation is selected us
-
ing the LR buttons and pressing ENTER.