Vertical results
l
(1) Flange correction in 0-6 direction
l
(2) Flange correction in 3-9 direction
l
(3) Bolt position
l
(4) Shimming values
l
(5) Coupling gap and offset in the 0-6 direction
l
(6) Coupling gap and offset in the 3-9 direction
l
(7) Shim correction modes
l
(8) Shim correction mode used in this example
l
(9) Initiates Live Move
l
(10) Tap the coupling results area to open the measurement table screen.
In the results screen, the three icons dimensions, measurement and results
are active and may be used anytime.
Shimming modes
Shimming modes are defined as follows:
l
(1) mode indicates all positive shimming
l
(2) mode indicates "zero/plus" shimming. In this mode, one bolt position is set to zero
and the rest are positive
l
(3) mode indicates optimized shimming. In this mode, half of the corrections will pos-
itive, and the other half negative.
l
(4)mode indicates "zero/minus" shimming. In this mode, one bolt position is set to zero
and the rest are negative.
l
(5) mode indicates all negative shimming
Sign convention
POSITIVE GAP opens towards 0:00 or 3:00
POSITIVE OFFSET if the top coupling half is offset towards 0:00 or 3:00
Fluke
831 105