EasyManuals Logo

Fluke 8808A User Manual

Fluke 8808A
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
v
List of Tables
Table Title Page
1-1. Safety Information ................................................................................................. 1-5
1-2. Safety and Electrical Symbols................................................................................ 1-6
1-3. Accessories............................................................................................................. 1-7
2-1. Line Voltage to Fuse Rating................................................................................... 2-4
2-2. Line-Power Cord Types Available from Fluke...................................................... 2-7
3-1. Front-Panel Features .............................................................................................. 3-4
3-2. Display Annunciators and Indicators ..................................................................... 3-7
3-3. Rear-Panel Features ............................................................................................... 3-8
3-4. RS-232 Pin Out ...................................................................................................... 3-17
3-5. RS232 Pin Out........................................................................................................ 3-19
3-6. Second Level Operations ....................................................................................... 3-21
3-7. List Editor Options................................................................................................. 3-23
3-8. Number Editor Options .......................................................................................... 3-24
3-9. Factory Power-Up Configuration........................................................................... 3-25
4-1. RS-232 Communication Parameters Factory Settings ........................................... 4-4
4-2. Print Rates in RS-232 Print-Only Mode ................................................................ 4-5
4-3. Trigger Types......................................................................................................... 4-9
4-4. RS-232 Reading Transfer Rates............................................................................. 4-10
4-5. Status Register Summary ....................................................................................... 4-11
4-6. Description of Bits in ESR and ESE ...................................................................... 4-14
4-7. Description of Bits in the Status Byte Register (STB)........................................... 4-14
4-8. Common Commands.............................................................................................. 4-16
4-9. Function Commands and Queries .......................................................................... 4-17
4-10. Function Modifier Commands and Queries ........................................................... 4-19
4-11. Range and Measurement Rate Commands and Queries ........................................ 4-21
4-12. Measurement Queries............................................................................................. 4-23
4-13. Compare Commands and Queries.......................................................................... 4-24
4-14. Trigger Configuration Commands ......................................................................... 4-24
4-15. Miscellaneous Commands and Queries ................................................................. 4-25
4-16. Measurement Units Output with Format 2............................................................. 4-25
4-17. Remote/Local Configuration Commands............................................................... 4-26
4-18. Save / Call System Configuration Commands....................................................... 4-26
Shop for Fluke products online at:
1.877.766.5412
www.MyFlukeStore.ca

Table of Contents

Other manuals for Fluke 8808A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 8808A and is the answer not in the manual?

Fluke 8808A Specifications

General IconGeneral
Product typeDigital multimeter
Product colorGrey, White
Frequency range0.2 - 2 kHz
AC current range0.2 - 10 A
AC voltage range0.2 - 750 V
DC current range0.0002 - 10 A
DC voltage range0.2 - 1000 V
Resistance range200 - 100000000 Ω
Placement supportedBench multimeter
Resistance resolution0.001 Ω
Resolution (frequency)0.0001 Hz
Resolution (AC current)100 µA
Resolution (DC current)1 µA
Resolution (DC voltage)1 mV
Basic accuracy (frequency)0.01%
Basic accuracy (DC current)0.02 + 0.005
Basic accuracy (DC voltage)0.015 + 0.003
Basic accuracy (resistance)0.02 + 0.003
Display digits5.5 digits
Weight and Dimensions IconWeight and Dimensions
Depth297 mm
Width217 mm
Height88 mm
Weight2100 g