Operating the Meter Using the Computer Interface
Status Registers 4
4-11
Status Registers
The contents of the status register (STB) are determined by the service enable register
(SRE), event status register (ESR), event status enable register (ESE), and the output
buffer. These status registers are explained in the following paragraphs and summarized
in Table 4-5.
Figure 4-2 shows the relationship of these registers.
Table 4-5. Status Register Summary
Register Read Command Write Command Enable Register
Event Byte Register *STB? None SRE
Service Request Enable
Register
*SRE? *SRE None
Event Status Register *ESR? None ESE
Event Status Enable
Register
*ESE? *ESE None