EasyManua.ls Logo

FOR-A MFR-3100EX - Main Unit Linking; Parallel Link System Example

FOR-A MFR-3100EX
86 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
35
3-2. Main Unit Linking
The Main Unit Link feature allows you to control multiple MFR-3100EX units at the same time.
Two types of system configurations are available:
Parallel Link:
Controls several MFR-3100EX units at the same time.
Expanded Matrix:
Creates an expanded virtual matrix by linking MFR-3100EX units.
Note that each Expanded Matrix system requires specific BNC connections. IP port and SNMP
settings should be performed on each MFR-3100EX unit. After these settings are completed, all
linked MFR-3100EX units are set and controlled together on the unit that is specified as Master.
Main Unit Link Specifications
- Main Unit Link systems are set and controlled through a specified master unit.
Up to 2 MFR-3100EX units can be linked within a system.
- Only SDI signals can be routed in Expanded Matrix systems.
- All MFR main units in a link system must be linked together and independent units cannot
exist in the system.
- If an option card of MFR-8SDIGB / 8SDOGB / 8SDODL / 8MADIPO / 8AESPO is installed,
the MFR main unit should behave as a Master.
3-2-1. Parallel Link System Example
The system example below is a redundant system using two MFR-3100EX units.
MFR-xxRU
Ethernet Hub (MFR-LAN)
Ethernet Hub (PC-LAN)
PC
MFR Web-based
Control
BB
MFR-LAN
PC-LAN
SDI
signal
REF IN
MFR-3100EX
(Master)
SDI
signal
192.168.0.13
192.168.1.11
192.168.1.21
192.168.0.23
MFR-LAN
PC-LAN
SDI
signal
REF IN
MFR-3100EX
SDI
signal
4
1
3
2
6
5

Table of Contents