3-4. Switcher's AUX Crosspoints Switching System
This system enables the following two features:
- Switches AUX crosspoints on a switcher using an MFR Series Remote Unit or serial
commands.
- Switches AUX crosspoints on a switcher as well as the corresponding crosspoints on the MFR-
3100EX, if the MFR-3100EX provides video sources to the switcher.
Supported switcher: HVS-100/110, HVS-390HS, HVS-490, HVS-1200, HVS-2000,
HVS-6000
◆ System Example
3-4-1. Switching an AUX Bus Signal
Assume that the system is configured as shown below:
AUX1 on the switcher is assigned to DST 129 (Level 1) on the MFR-3100EX.
IN1-8 and STL(Still) 3 on the switcher are assigned to SRC129-137 on the MFR-3100EX.
SDI
PGM
Monitor
VIDEO(SDI)
LAN
(MFR-LAN)
LAN (PC LAN)
PRV
Monitor
SDI
SDI signal
MFR-3100EX
MFR-8SDI
IN1
|
|
|
|
I
|
|
I
|
IN64
MFR-8SDO
OUT1
|
|
|
|
I
|
I
|
|
OUT72
SDI signal
Video Switcher
(HVS-390HS)
SDI
AUX1
AUX2
AUX3
AUX4
AUX5
AUX6
REF IN
LAN
BB
MFR-xxRU
MFR-LAN1 (31CPU)
MFR-LAN2 (3100EX)
PC-LAN1(31CPU)
PC-LAN2(3100EX)
PC
MFR Web-based Control
Ethernet Hub (PC-LAN)
Ethernet Hub (MFR-LAN)
DST129
AUX1
SRC129
IN1
HVS-390HS
SRC130
AUX2
IN2
|
|
|
SRC137
STL3