F3D3 Series Service Manual - Propane Service Restrictions / Section 4.0
Questions? Call Franke Technical Support Group For Your Area. Copyright 2012 Franke, Inc. All rights reserved.
4.0 Models Charged with R-290 Propane ONLY
SERVICE RESTRICTIONS
Model F3D3P and F3D3SP refrigeration systems are charged
with R290 PROPANE refrigerant. It is strictly forbidden to
test or repair the F3D3P or F3D3SP Refrigeration System.
Certain requirements apply to work (analysis/repair) on
cooling systems that must be strictly observed. If these
requirements are not fulfilled, the warranty will be void and
Franke accepts no liability.
- Work on cooling system must never be carried out in the
restaurant.
- The unit may be repaired in a suitable workshop. It is
important to ensure there is sufficient ventilation.
- The unit may only be kept outside in the open air for the
duration of the work on the cooling system.
- The work may only be done by a qualified (certified)
specialist company, in accordance with all local laws and
standards that may apply.
The only refrigeration system-related service allowed on
the R290 PROPANE filled condenser systems are the PM
procedures describe in the F3D3P/SP Operating Manual
and repeated as Section 4.1 (Preventive Maintenance) of this
Service Manual. If those steps do not resolve a
refrigeration system problem, contact the Franke
Technical Support Group.
[Photo 1] From left side
The exterior of propane models
have warning stickers to indicate
the potential flammability hazard
of R290 Propane.
[Photo 2] From rear of unit
Key refrigeration lines are
tagged with warnings (in three
languages) of the potential
hazards of R290 Propane and
the need to contact the Franke
Technical Support Group.
[Photo 3] Don’t Remove Tags
DO NOT OPEN or attempt
to service the R290
Propane filled Refrigeration
Package.
Rev. 1 6/2012
WARNING - Danger of fire!
F3D3P and F3D3SP Model refrigeration
systems are filled with R290 (propane).
Propane is highly flammable.
Work (analysis/repair/maintenance) on
the cooling system is only allowed under
certain conditions!
- Never repair the cooling system yourself.
- If you experience problems, contact
Franke Technical Support. The unit may
only be repaired by a refrigeration
technician under certain conditions.

Table of Contents

Other manuals for Franke F3D3P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Franke F3D3P and is the answer not in the manual?

Franke F3D3P Specifications

General IconGeneral
BrandFranke
ModelF3D3P
CategoryDispenser
LanguageEnglish

Related product manuals