F3D3 Series Service Manual - Factory Lev3 Parameter Access / 1.11.1
Questions? Call Franke Technical Support Group For Your Area. Copyright 2012 Franke, Inc. All rights reserved.
Parameter Access & Programming
F3D3 Series Fries Dispensers provide easy
access to Factory Level operating and
service diagnostic parameters using the
front operator interface touch panel &
display. To access:
1) Leave unit plugged in.
2) Turn Main Power Switch ON.
3) Lane power must be OFF. Display will
be blank or show current freezer
temperature, depending on the lane.
To Access Factory Level 3 Parameters:
From Standby condition use 3
rd
touchpad to
enter: 3 3 3 3. [The Entry Code]
Special Mode Select
Cust Fact Exit
Press touchpad 2 = Fact(ory)
Factory Access Level
Lev1 Lev3 Exit
3
Enter Password 0 _ _ _
4A
Press touchpad 2 = OK [Icon will move right to
next digit]
Enter Password 0 0 _ _
4B
Press touchpad 2 = OK [Icon will move right to
next digit]
Enter Password 0 0 0 _
4C
Press touchpad 2 = OK [Icon will move right to
last digit], then:
Enter Password 0 0 0 0
4D
Press touchpad 1 = Inc once, to raise to 1,
then:
Enter Password 0 0 0 1
5
Language [first Parameter]
P01 = English
See Parameter Spreadsheet for P-numbers, functions & default settings.
NOTE Software Codes and exceptions that apply.
Command Key: ++ to scroll up; -- to scroll down; -> to move flashing
underscore __ under next value; == to accept or OK value or setting
Set Point
Press 1 = ++ to increase temp. value [-0004]
Press 2 = -- to decrease temp. value [- 0006 ]
Press 3 = == to accept (new) setting
Set Point [Refrigerator temp.]
P02 = -0005 F
Rev. 1 6/2012
NOTE: All programming is done using the
three choice buttons labeled: 1, 2 and 3 above.