27
General: Thermostat Configuration
Conguring the Equipment Settings
Enter the equipment code by changing the digits on the screen. Refer to the table
below.
Press the FAN button to advance to the next equipment setting.
Press the UP and DOWN buttons to increase or decrease the value;
Press the F|C button to advance to the next menu.
The table below explains each digit of the equipment settings:
NOTE:
Digit
Value
Digit #1
Compressor Type
Digit #2
Electric Heat
Digit #3
Reversing Valve
Digit #4
# of Fan Speeds
0 No Compressor No Electric Heat
O/B Contact is energized
to cool
N/A
1 Heat Pump Has electric Heat
O/B Contact is energized
to heat
1
2 Air Conditioner* N/A N/A 2
IMPORTANT: INSERTING THE WRONG EQUIPMENT CODE MAY CAUSE THE
HVAC UNIT NOT OPERATING AS EXPECTED.
Digit #3 Reversing Valve makes a difference ONLY when a Compressor Type
(Digit#1) is set to Heat Pump (digit value 1).
Please refer to the next page for all equipment codes.