Product Type HVAC Controller Gateway
SKU(s)
HVAC Controller for DSSXEMWRT3
HVAC Controller for VRPXEMWRT3
HVAC Controller for FreshAire
EMOCT3
Wireless Frequency 902-928MHz (NA) N/A
Case Dimensions
(Imperial)
4.08” x 2.76” x 1.02” 4.72” x 3.15” x 1.18”
Case Dimensions (Metric) 104mm x 70mm x 26mm 120mm x 80mm x 30mm
Screen Dimensions
(Imperial)
N/A N/A
Screen Dimensions
(Metric)
N/A N/A
Operating Voltage
24VAC (20-30VAC) | 12VDC ( 9-15VDC)
5VDC*
12VDC 1.5A
Control Outputs
(24VAC)
(1.5A maximum per
terminal, 2.5A maximum
all terminals combined)
Fan High (GH)
N/A
Fan Low (GL)
Compressor (Y)
Heat Pump (OB)
Electric Heat (W2)
Occupancy Out (AUX1)
Power Supply Outlet
12VDC @ 0.05A (Max)
Occupancy Sensor Beam
Width
N/A
Temperature Accuracy ±1°F
Enclosure Material ABS Extruded Aluminum
Ambient Operating Temp 32°F -105°F | 0 - 41°C 32°F -105°F | 0 - 41°C
Internet Connectivity N/A 100M/1000M Base-T Ethernet
FCC ID XEY-ZX-LV
IC 8410A-ZX-LV
Technical Specifications
* certain functions are not available with 5VDC input