Name S3 Turbo 30
S3 Turbo 30
1)
Nominal output kW 30 31
Electrical connection 230V / 50Hz / fused C13A
Power consumption at nominal load W 51 49 - 70
Power consumption in slumber mode 3
Weight of boiler incl. insulation and control kg 530
Total boiler capacity (water) l 120
Water pressure drop (ΔT = 10 / 20 K) mbar 6.1 / 2.0
Minimum boiler return temperature °C 60
Maximum permitted operating temperature 90
Permitted operating pressure bar 3
Airborne sound level dB(A) < 70
Permitted fuel as per EN ISO 17225 Part 5: Firewood class A2 / D15 L50
Fuel loading door dimensions (width / height) mm 330 / 370
Fuel loading chamber capacity l 140
Combustion time
2)
- beech
h 3.9 - 5.6
Combustion time
2)
- spruce
2.8 - 3.9
1.S3 Turbo 30 with 31 kW nominal output only available in Austria and Italy
2.
Values specified for combustion time are guideline values at nominal load and will vary depending on water content (15-25%) and fill level
(80-100%)
Regulation (EU) 2015/1187
Energy efficiency A+ A+
Rated heat output kW 30 31
Energy efficiency index of the boiler model 117 115
Seasonal space heating energy efficiency % 80 78
Energy efficiency index of the boiler in package with
temperature control
119 117
Energy efficiency class of the boiler in package with
temperature control
A+ A+
S3 Turbo 30
Technology
3
Technical specifications
Installation Instructions S3 Turbo | M1081217_en 19

Table of Contents

Other manuals for Froling S3 Turbo

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Froling S3 Turbo and is the answer not in the manual?

Froling S3 Turbo Specifications

General IconGeneral
BrandFroling
ModelS3 Turbo
CategoryBoiler
LanguageEnglish

Related product manuals