4.5.9 Installing the cleaning port door and blank cover
NOTICE! Recommendation for easier maintenance: mount the cleaning door on the
same side as the WOS lever!
Use three Allen screws to mount the cleaning door on the desired side
Start with the screws at upper right!
Attach the door handle for the cleaning door using a round headed screw (A)
Install the blank cover for the side cleaning on the opposite side
4.5.10 Installing the insulated door
The illustrations show the assembly for the door stop on the right. If the insulated door
is attached on the left, complete the following procedures with the sides reversed
accordingly.
Tap in a fitting grooved pin (A) at the lower door bracket
Slide the lower door bracket into the base of the boiler
Insert the fitting grooved pin (A) into the insulation
Lightly tighten the two hexagonal screws M6 x 12 (B)
S3 Turbo 20/30:
Assembly
4
Installing the boiler
Installation Instructions S3 Turbo | M1081217_en 45