Adress Description Read Write Group Unit Type Factor
E04C Dutycycle [dcY] True True TIG / HAP Word 1
E04D Background current [I-G] True True TIG / HAP % Word 1
E04E Gas prefl ow [GPr] True True TIG / HAP s Word 0,1
E04F Gas postfl ow high [G-H] True True TIG / HAP s Word 0,1
E050 Gas postfl ow low [G-L] True True TIG / HAP s Word 0,1
E051 Gas commandvalue [GAS] True True TIG / HAP l Integer 0,01
E052 Gasfactor [Cor] True True TIG / HAP Integer 0,1
E053 Tacking time [tAC] True True TIG s Word 0,1
E054 Needle diameter [Eld] True True TIG / HAP mm Word 0,1
E055 Guntrigger mode True True TIG / HAP Word 1
0 2-step
1 4-step
E056 Spot time [SPt] True True TIG s Word 0,01
E057 Standard-TIG / HAP Cooling unit True True TIG / HAP Word 1
cut-out [C-C]
E058 Calotte True True TIG Boolean 1
E059 Comfort Stop Senesitivity [CSS] True True TIG V Integer 0,01
E05A Ignition timeout [Ito] True True TIG / HAP s Word 0,1
E05B Arc break watchdog [Arc] True True TIG / HAP s Word 0,1
E05C Special 4-step [SFS] True True TIG Word 1
E05D External parameter [E-P] True True TIG / HAP Word 1
E05E Phase [PHA] True True TIG / HAP Word 1
only available on 3-phase
powersources!
E05F Reverse polarity ignition [rPi] True True TIG Boolean 1
E060 HF-time True True TIG / HAP ms Word 1
E061 True True TIG / HAP mOhm Word 0,1
E062 Feeder 1 [Fd.1] True True TIG m/min Integer 0,01
E063 Feeder 2 [Fd.2] True True TIG % Word 1
E064 Inching speed [Fdi] True True TIG m/min Word 0,01
E065 Feeder-delay 1 [dt1] True True TIG s Word 0,1
E066 Feeder-delay 2 [dt2] True True TIG s Word 0,1
E067 Feeder back [Fdb] True True TIG mm Word 1
E09F Pre-HF-time True True TIG / HAP s Word 0,1
E0A0 Spezial-2-step True True TIG Word 1
E0AB Gas purge True True TIG / HAP Word 1
E0C2
Welding-circuit inductance TIG/HAP
True False TIG / HAP µH Word 0,01
E0CC Ioff set [Io] True True TIG A Integer 1
E0D2 Start current [l-S] True True TIG % Word 1
ATTENTION: there are two
diff erent values for AC and DC,
so change ACMODE before
changing this value
E0D3 Upslope time [UPD] True True TIG / HAP s Word 0,01
ATTENTION: there are two
diff erent values for 2-step and
4-step, so change GUNMODE
before changing this value
Welding-circuit resistanceTIG/HAP
213