Adress Description Read Write Group Unit Type Factor
E08D Current rise tau True True MigMag ManPULS ms Word 0,01
E08E Pulsing current True True MigMag ManPULS A Integer 0,1
E08F Pulsing current time True True MigMag ManPULS ms Word 0,01
E090 Current decrease True True MigMag ManPULS A/ms Word 0,1
E091 Current drop tau True True MigMag ManPULS ms Word 0,01
E092 Droplet detachment current True True MigMag ManPULS A Integer 0,1
E093 Droplet detachment time True True MigMag ManPULS ms Word 0,01
E094 Pulsing frequency True True MigMag ManPULS Hz Word 0,1
E095 Wirefeed speed True True MigMag ManPULS m/min Integer 0,01
E096 Voltage command value True True MigMag ManPULS V Integer 0,01
E097 Fact I_b_control_pi True True MigMag ManPULS % Word 0,01
E098 Fact I_p1_control_pi True True MigMag ManPULS % Word 0,01
E099 Fact f_control_p True True MigMag ManPULS % Word 0,01
E09A Fact I_b_correction True True MigMag ManPULS % Word 0,01
E09B Fact I_p1_correction True True MigMag ManPULS % Word 0,01
E09C Fact f_correction True True MigMag ManPULS % Word 0,01
E09D Current rise sc True True MigMag ManPULS A/ms Word 0,1
E09E Burn back time True True MigMag ManPULS s Word 0,01
E0A1 Regulator output True True MigMag ManPULS Integer 1
E0A3 Gas prelow [GPr] True True Pilot Plasma s Word 0,001
E0A4 Gas postfl ow [GPo] True True Pilot Plasma s Word 0,001
E0A5 Gas commandvalue [GAS] True True Pilot Plasma l Integer 0,01
E0A6 Gasfactor [Cor] True True Pilot Plasma Word 0,1
E0A7 Pre-/Post Gas True True Pilot Plasma l Integer 0,01
commandvalue [GPA]
E0A8 Pilot current True True Pilot Plasma A Integer 0,1