Page #15 background imageLoading...
Page #15 background image
ud_fr_st_sv_00467 012010
XI
With parts sourced from other suppliers, there is no certainty that these parts
will have been designed and manufactured to cope with the stressing and
safety requirements that will be made of them. Use only original spares and
wearing parts (this also applies to standard parts).
Do not make any alterations, installations or modifications to the machine
without getting permission from the manufacturer first.
Replace immediately any components that are not in perfect condition.
When ordering spare parts, please state the exact designation and the
relevant part number, as given in the spare parts list. Please also quote the
serial number of your machine.
Preventive and
corrective main-
tenance
- If any damage occurs in cases where other coolants have been used, the
manufacturer shall not be liable for any such damage, and all warranty
claims shall be null and void.
- Under certain conditions, the coolant is flammable. Only transport the
coolant in closed original containers, and keep it away from sources of
ignition.
- Used coolant must be disposed of properly in accordance with the
relevant national and international regulations. A safety data sheet is
available from your service centre and on the manufacturer’s homepage.
- Before starting welding - while the machine is still cool - check the
coolant level.
Safety precauti-
ons in normal
operation
(continued)
The manufacturer recommends that a safety inspection of the device is
performed at least once every 12 months.
The manufacturer recommends that the power source be calibrated during
the same 12-month period.
A safety inspection should be carried out by a qualified electrician
- after any changes are made
- after any additional parts are installed, or after any conversions
- after repair, care and maintenance has been carried out
- at least every twelve months.
For safety inspections, follow the appropriate national and international
standards and directives.
Further details on safety inspection and calibration can be obtained from your
service centre. They will provide you on request with any documents you may
require.
Safety inspection
Do not dispose of this device with normal domestic waste!
To comply with the European Directive 2002/96/EC on Waste Electrical and
Electronic Equipment and its implementation as national law, electrical
equipment that has reached the end of its life must be collected separately
and returned to an approved recycling facility Any device that you no longer
require must be returned to our agent, or find out about the approved collec-
tion and recycling facilities in your area.
Ignoring this European Directive may have potentially adverse affects on the
environment and your health!
Disposal

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius PlasmaModule 10 and is the answer not in the manual?

Fronius PlasmaModule 10 Specifications

General IconGeneral
BrandFronius
ModelPlasmaModule 10
CategoryWelding System
LanguageEnglish

Related product manuals