The Setup menu
General remarks
Parameters for plasma gas supply
GPr
Gas pre-flow time - Plasma gas pre-flow time
Unit s
Setting range 0 - 9,9
Factory setting 0,4
GPo
Gas post-flow time - Plasma gas post-flow time
Unit s
Setting range 0 - 9,9
Factory setting 5
GPU
Gas purger - Plasma gas purging
Unit min
Setting range OFF / 0.1 - 10.0
Factory setting OFF
Plasma gas purging begins as soon as GPU is allocated a value.
For safety reasons, plasma gas purging cannot be restarted until a new GPU value is
entered.
Important! Plasma gas purging is necessary above all where condensation forms after
the device has been left unused in a cold environment for a long time. Long hosepacks
are most affected.
The Setup menu makes it easy to adapt the parameters saved in the unit to different
types of task:
- The plasma gas supply parameters are set in the Gas Setup.
- The Setup menu contains parameters which have an immediate effect on the
plasma process.
- Machine pre-sets are defined in the Setup menu level 2 (2nd).
Gas Setup 1. To enter Gas Setup, press the Store button and the Gas Test
button simultaneously.
The plasma gas setting parameter last called is displayed.
2. Select parameter by pressing the Gas Test button
3. Change the parameter values by using the adjusting dial
4. Press the Store button to exit Gas Setup
+