25
Troubleshooting
WARNING! An electric shock can be fatal. Before opening up the machine
- Move the mains switch to the “O” position
- Unplug machine from the mains
- Put up an easy-to-understand warning sign to stop anybody inadvertently
switching it back on again
- Using a suitable measuring instrument, check to make sure that electrical-
ly charged components (e.g. capacitors) have been discharged
CAUTION! Failure to connect an appropriate earth lead may result in serious
injury or damage. The housing screws provide a suitable PE conductor connec-
tion for earthing (grounding) the housing and must NOT be replaced by any
other screws which do not provide a reliable PE conductor connection.
General remarks The digital PlasmaModule 10 is equipped with an intelligent safety system that does not
require fuses.
After a possible malfunction has been remedied, PlasmaModule 10 can be put back into
normal operation again without any fuses having to be changed.
Service codes
displayed
If any error message that is not described here appears on the displays, then the fault is
one that can only be put right by a service technician. Make a note of the error message
shown in the display, and of the serial number and configuration of the PlasmaModule,
and get in touch with our after-sales service, giving them a detailed description of the
error.
tP1 | xxx
Cause: Overheating in the primary circuit of PlasmaModule 10
Remedy: Allow PlasmaModule 10 to cool down
tS1 | xxx
Cause: Overheating in the secondary circuit of PlasmaModule 10
Remedy: Allow PlasmaModule 10 to cool down
tSt | xxx
Cause: Overheating in the control circuit of PlasmaModule 10
Remedy: Allow PlasmaModule 10 to cool down
Err | 051
Cause: Mains undervoltage: The mains voltage has dropped below the tolerance
range (see chapter „Technical data“)
Remedy: Check the mains voltage
Err | 052
Cause: Mains overvoltage: The mains voltage has exceeded the upper limit of the
tolerance range (see chapter „Technical data“)
Remedy: Check the mains voltage

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius PlasmaModule 10 and is the answer not in the manual?

Fronius PlasmaModule 10 Specifications

General IconGeneral
BrandFronius
ModelPlasmaModule 10
CategoryWelding System
LanguageEnglish

Related product manuals