20
Setup menu level
2 (2nd)
(continued)
Parameters for machine pre-sets
C-C
Flow monitoring
Unit -
Setting range ON / OFF
Factory setting ON
„ON“ position Flow monitoring remains permanently switched on
„OFF“ position Flow monitoring remains permanently switched off
COr
Correction - Gas correction
Unit -
Setting range AUT / 1.0 - 10.0
Factory setting AUT (corresponds to a correction factor of 1.76 and therefore argon
100 %)
Other correction factors for other plasma gases can be found in the table of correction
factors.
SEt
Setting - Country-specific setting (Standard / USA)
Unit -
Setting range Std / US
Factory setting Standard version: Std (l/min)
USA-Version: US (cfh)
Ito
Ignition Time-Out - Time until safety cut-out following an abortive ignition attempt
Unit s
Setting range 0,1 - 9,9
Factory setting 5
Important! „Ignition Time-Out“ is a safety function so cannot be deactivated. A descripti-
on of the „Ignition Time-Out“ function may be found in the section headed „TIG welding“.
Arc
Arc - Arc break watchdog: Time until safety cut-out following an arc break
Unit s
Setting range 0,1 - 9,9
Factory setting 2
Important! The arc break watchdog is a safety function so cannot be deactivated.
4. Select parameters by pressing the Start / Stop button
5. Change the parameter values by using the adjusting dial
6. To exit Setup menu level 2: press the Store button twice
- press once = return to Setup menu, „2nd“ parameter
- press twice = return to normal mode