Care, maintenance and disposal
General The cleaning device generally needs no maintenance. However, to keep the cleaning de-
vice in good working condition for years to come, several points on care and maintenance
must be observed.
Before each start-
up
- Check the cleaning brushes on the brush head and replace worn brushes
- Empty the cleaning device spatter tray
- If fitted, empty the wire cutter tray
- Carry out a general visual inspection of the cleaning device and wire cutter
Daily - Remove any dirt deposits from device
Every 6 months Open the device and check the pneumatic valves for:
- leaks
- the secure seating of all screws
- the secure seating of all screw joints on the pneumatic valves
If necessary Open the device and
- clean the inside of the device using dry reduced compressed air
- lightly oil the lifting device cylinder guides
Changing the end
brushes (stand-
ard brush head
only)
Remove the protective covering from the cleaning device
5 6
Fit the protective covering to the cleaning device in its original position
1
2 3
4