EasyManua.ls Logo

Fronius Selectiva 4185 - Page 22

Fronius Selectiva 4185
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22
(10) Control panel
(11) Optional LED strip
Lights up in different colours depending on the state of charge, as explained in the
"Control panel" section
WARNING!
Danger from electric current.
This can result in serious injury or death.
Only trained service technicians may open the housing. This includes removing the
connection plate.
The device must be disconnected from the mains before starting any work with the
housing open.
A suitable measuring instrument must be used to ensure that electrically charged com-
ponents (e.g. capacitors) are fully discharged.
Use an easily legible and understandable warning sign to ensure that the device is not
reconnected to the mains supply before all the work has been completed.
WARNING!
Danger due to work that has been carried out improperly.
This may result in serious injury and damage to property.
Connection work on the device must only be carried out by qualified specialist techni-
cians.
If there are Installation Instructions or User Information for the optional component con-
cerned, then all warning notices and instructions therein must be obeyed.
Once the connection work is complete, a safety inspection must be carried out in ac-
cordance with relevant national and international standards and directives.
Further details on safety inspections can be obtained from your authorised service cen-
tre.
They will provide you with any documents you may require on request.
* The CAN connection area can only be accessed by removing the connection plate on
the front of the device. The following warning notices must be obeyed:
The figure shows the connections in the
CAN connection area.
The CAN connection area is located be-
hind the connection plate on the front of
the device. The warning notices listed
above apply to the CAN connection area.
(2) External start/stop (+) - black
(3) External start/stop (-) - black
(5) Detect - white
(6) CAN High - green
(7) CAN Low - yellow
(8) CAN GND - brown
(2)
black
white
Ext. Start/Stop (-) black
Detect
42,0409,0411
CAN High green
CAN Low yellow
CAN GND brown
(3)
(5)
(6)
(7)
(8)
Ext. Start/Stop (+)