AC power limit:
- Requirement: "Charge" is selected
- A maximum value for AC power can be set for each time window. The charger may
not exceed this value during this phase.
The AC power limit can be set in stages of
0.5 kW.
The minimum and maximum values differ
depending on the different device classes.
The minimum value is approx. 25% of the
maximum output power of the charger.
Please note! Setting a power limit can have a negative effect on the charger's efficiency.
Week setting:
- Three different week settings can be
defined.
A previously created day setting can be as-
signed to any day of the week.
Year setting:
- Multiple periods throughout the year
may be defined, each containing a
single week setting (e.g. 1/1 - 7/1).
When the calendar function is active, a calendar symbol appears on the display.
Disable Start Button:
- ON:
- The charging process cannot be started using the "Stop/Start" key; one reason
for this is to prevent unauthorised intervention.
- OFF:
- The charging process can be started using the "Stop/Start" key
Check DC-Connection:
- ON:
- An error is output if an open circuit is detected several times per charging action
and the battery remains connected throughout (e.g. poor plug contact)
- OFF:
- An error is not output if an open circuit is detected.