NOTE!
A standard value setting of 2.
0 is recommended for the CSS parameter. However, if the welding process is frequently
stopped unintentionally, increase the value for the CSS parameter.
Depending on the value of the CSS parameter, it may be necessary to lengthen the arc
to trigger the TIG comfort stop function:
- when CSS = 0.5 - 2.0 ......... small increase in the size of the arc
- when CSS = 2.0 - 3.5 ......... medium increase in the size of the arc
- when CSS = 3.5 - 5.0 ......... large increase in the size of the arc
r
r (resistance) - Welding circuit resistance (in mW)
see "Measuring welding circuit resistance r"
L
L (inductivity) - Welding circuit inductivity (in microhenry)
see "Displaying welding circuit inductivity L"
COr
Correction - Gas correction ("Digital gas control" option)
Unit -
Setting range AUT / 1.0 - 10.0
Factory setting AUT
NOTE!
Please refer to "Digital Gas Control" operating instructions for more detailed
explanations of the "COr" parameter.
Parameters for
rod electrode
(MMA) welding in
the Setup menu
level 2
Eln
Electrode line - characteristic selection
Unit 1
Setting range CON or 0.1 - 20 or P
Factory setting CON
158
Toowoomba Welding Supplies : tweld.com.au : Ph +61 7 4659 0044

Table of Contents

Other manuals for Fronius TransPuls Synergic 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius TransPuls Synergic 5000 and is the answer not in the manual?

Fronius TransPuls Synergic 5000 Specifications

General IconGeneral
BrandFronius
ModelTransPuls Synergic 5000
CategoryAC Power Distribution
LanguageEnglish

Related product manuals