Documentation - The electrician who carried out the inspections is responsible for documenting them
correctly
- All inspections carried out are to be documented in an inspection log. The measured
values as well as the inspection equipment used, and calibration data must be given
- If an individual inspection cannot be carried out, reasons for the examiner's decision
are to be documented
- If the inspection is not passed, then the device in question must be clearly identified
as unsafe and the operator must be informed. The equipment must no longer be op-
erated.
- If the inspection is passed, mark the device with the inspection sticker (42.0409.3688).
The "Safety Inspection" inspection log can be found in the DownloadCenter.
Inspection sticker After the inspection is passed, the respective inspection sticker must be visibly attached to
the housing in accordance with PMÜ-01.