Service-menu
Level P1
Service-menu with various test programs
You can find a detailed description of the service menu in the Operating Instructions
“Set-up functions / Error indications”, which are available as on option (42,0410,0494).
- With button (4) pressed, switch on the machine
- --- appears -> “Presettings“ level
- Press and hold down the torch trigger until
1. P1 appears -> Service-menu level
2. P1 appears -> Codelock level
3. --- appears again -> Presettings level
- Release button (4)
Working with the program levels
Accessing the
relevant program
level
Presettings
level ---
Use button (4) to select the parameters, and the torch trigger to change their values.
Only the parameters for the operating mode that is set (TIG/ Electrode) are shown.
Parameters for TIG operating mode DC
GAS Gas pre-flow 0-20s.
G-L Gas post-flow at I
min
2,0-26s.
G-H Gas post-flow at I
max
2,0-26s.
UPS Up-slope 0,1-7s.
SCU Start Current - Start arc 0-100%
I3 Reduced current, 0-100% of I
H
HFt Time of HF-period (from 0,01-0,4s)
SCU Starting current - As absolute value of max. main current (160A/170A)
As relative value of pre-set main current
StS Special 2-step mode ON/OFF
SFS Special-4-step mode OFF/1/2/3/4/5
ELd Diameter of tungsten electrode (from 0-3,2mm)
PRO Program - For storing the parameters, once these have been set, by pressing the
torch trigger
FAC Factory - For activating the parameters pre-set by Fronius, by pressing the torch
trigger
Parameters for electrode operating mode
Hti Hotstart time 0,2-2s
HCU Hotstart current 0-100%
dYn Arcforce dynamic 0-100A
PRO Program - For storing the parameters, once these have been set, by pressing the
torch trigger
FAC Factory - For activating the parameters pre-set by Fronius, by pressing the torch
trigger.
Parameters of the pre-set Fronius-program (FAC)
GAS 0,4s SCU rEL
G-L 5,0s StS OFF
G-H 15,0 SFS OFF
UPS 1,0s ELd 2,4mm
SCU 29% Hti 0,5s
I3 50% HCU 50%
HFt 0,01s dyn 30A

Other manuals for Fronius TransTig 1700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius TransTig 1700 and is the answer not in the manual?

Fronius TransTig 1700 Specifications

General IconGeneral
BrandFronius
ModelTransTig 1700
CategoryWelding System
LanguageEnglish

Related product manuals