Care, maintenance and disposal
General remarks
Every start-up
Every 2 months
Every 6 months
Disposal
Under normal operating conditions the power source requires only a minimum of care
and maintenance. However, it is vital to observe some important points to ensure the
welding machine remains in a usable condition for many years.
- Check mains plug, mains cable, welding torch, interconnection cable assembly and
bondings for damage
- Check that there is a gap of 0.5 m (1.6 ft.) all around the machine to ensure that
cooling air can flow and escape unhindered.
NOTE! Air inlets and outlets must never be covered, not even partly.
- Optional: clean air filter
- Dismantle machine side panels and clean machine inside with dry reduced com-
pressed air
NOTE! Risk of damage to electronic components. Do not bring the air nozzle
too close to the electronic components.
- If a lot of dust has accumulated, clean the cooling air ducts.
Dispose of in accordance with the applicable national and local regulations.
WARNING! An electric shock can be fatal. Before opening the machine
- Switch the mains switch „OFF“
- Unplug machine from the mains
- Put up an easy-to-understand warning sign to stop anybody inadvertently
switching it back on again
- Using a suitable measuring instrument, check to make sure that electrical-
ly charged components (e.g. capacitors) have been discharged

Other manuals for Fronius TransTig 1700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius TransTig 1700 and is the answer not in the manual?

Fronius TransTig 1700 Specifications

General IconGeneral
BrandFronius
ModelTransTig 1700
CategoryWelding System
LanguageEnglish

Related product manuals